Replacing Two Rolled Steel Joists with One RSJ: What a Structural Engineer Needs to Calculate

8/10/2026

0 Comments

 
Picture
If you're renovating an older property in Basildon, Billericay or anywhere else across Essex, there's a good chance you'll come across a section of the house held up by two separate steel beams rather than one. 

This was a fairly common approach decades ago, particularly where openings were widened in stages or where the original builder simply worked with what was available at the time. It's not unusual for homeowners to look at this setup and wonder whether it could be simplified by replacing two steel beams with one RSJ (Rolled Steel Joist). It can often be done, but it's not a job to approach without professional RSJ calculations.

Understanding the Existing Load Path
The first thing a structural engineer Essex homeowners trust will look at is exactly what those two beams are currently doing. It sounds obvious, but it's easy to underestimate. Are they both carrying the same load, or is one taking more weight than the other because of how the floor joists or roof timbers above are arranged? 

Before any replacement can be specified, the engineer needs an accurate picture of the total load being transferred down through that section of wall. They also need to check the dead loads from the structure itself, plus live loads from occupants, furniture and anything stored in the loft space above.

Sizing the Replacement Beam
Once the total load is understood, the next step is sizing the replacement beam itself. This isn't a case of picking ‘one big beam’ and assuming it'll cope. The engineer needs to calculate the bending moment and shear force acting across the span. Only then can they select a steel section with sufficient depth and flange width to carry the load safely without excessive deflection. 

Deflection matters more than people realise. Too much flex in a beam can crack plaster, cause doors to stick or create visible sagging over time, even if the beam is technically strong enough not to fail. Accurate RSJ calculations ensure the replacement beam performs safely without long-term structural issues.

Checking the Bearing Points
The bearing points are another critical consideration. A single RSJ concentrates the load onto two bearing points instead of however many the original two beams used. That means the padstones or bearing plates at each end need recalculating too, to make sure the walls or piers beneath can actually take that concentrated load without crushing or settling.

Planning the Removal Sequence
There's also the practical side of removal and installation. Taking out two existing beams safely, usually while temporarily supporting the structure above with acrows or needling, requires a proper sequence of works. An engineer will include this within the structural design and RSJ calculations, because the method of removal directly affects the safety of the works.

Building Control Approval in Essex
Finally, in Essex, any structural alteration typically needs Building Control sign-off. A structural engineer Essex homeowners rely on will usually prepare calculations and drawings specifically formatted for Building Regulations approval, so the whole process fits together properly rather than causing delays further down the line. Getting this right from the outset saves both time and money. 
​
Need expert advice before replacing two steel beams with one RSJ? Contact Essex Structural Engineers today. Our experienced team provides accurate RSJ calculations, structural designs and Building Regulations documentation for homeowners across Essex.



0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    Topics

    All
    Civil Engineers
    Commercial
    Design
    Load Bearing Walls
    Lofts
    Residential
    Solar Panels
    Structural Engineers
    Top Tips

Essex Structural Engineers

​Jubilee House
3 The Drive
Great Warley
Brentwood
Essex, CM13 3FR

Picture
QUICK LINKS

Home
About
Commercial projects
Residential projects
Design Consultancy
Building regulations advice
Portfolio
Areas we cover
Blog
​Contact

GET IN TOUCH
​

[email protected]
01277 554 147
Privacy Policy
Designed and created by Perfect Layout Digital Marketing. Copyright​©2026. All rights reserved.
  • Home
    • About
    • Frequently Asked Questions
  • Services
    • Commercial Projects >
      • Business Park Developments
      • Leisure and Gym Facilities
      • Office Space
    • Residential Projects >
      • Domestic Alterations
      • Extensions
      • Loft Conversions
      • New Build and Self Build
      • Retaining Walls
    • Design Consultancy
    • Building Regulation Advice
  • Portfolio
  • Areas
    • Basildon
    • Billericay
    • Brentwood
    • Chelmsford
    • Chipping Ongar
    • Epping
    • Grays
    • Loughton
    • Rainham
    • Romford
    • Upminster
  • Blog
  • Contact